AE-TECHRON 7794 200 AMP, 5 kW, DC-enabled Linear Power Amplifier
Specifications
Frequency Response: DC – 30 kHz, +0.1, –0.5 dB
8 ohm Power Response:
- DC-50 kHz: ± 95 Vpk
- DC-150 kHz: ± 50 Vpk
- DC-200 kHz: ± 25 Vpk
Maximum Continuous Output Power: 5000 watts RMS
Slew Rate: 41 V/μSec
Phase Response: ±8.3 degrees (10 Hz – 10 kHz)
Phase Error: ±0.1 degrees at 60 Hz
Output Offset: Less than 5 mV, field adjustable to less than 1 mV
Unit to Unit Phase Error: ±0.1 degrees at 60Hz
Output Offset: Less than 5 mV, field adjustable to less than 1 mV
Output Offset Current: Less than 10 mA DC
DC Drift: ±1.5 mV
Residual Noise:
- Unfiltered: Less than 75 μV
- Filtered (400 Hz – 30 kHz): Less than 55 μV
THD: DC - 30 kHz less than 0.1%
AE Techron's 7794 is a powerful four-quadrant amplifier that offers up to 200 Ap power, DC –100 kHz bandwidth, and controlled-current or controlled-voltage modes of operation. The 7796 works best into loads of 0.5 ohms or less. For greater voltage or current (up to 800 Ap) units can be combined in parallel or series.
Typically used when large currents are needed to drive very low impedances for long periods of time. Often used as a battery substitute for transient immunity testing requiring a battery as specified in EMC Test Standards for military, aviation and the automotive industries.
Features:
- Stable when driving a wide range of resistive, inductive or capacitive loads
- 60A continuous at 13.8 VDC
- 200A in-rush current capability
- 150 kHz small signal bandwidth
- ±95 VDC capable
- 41 V/μS slew rate
- Four-quadrant operation (source and sink)
AE Techron's 7794 is a powerful four-quadrant amplifier that offers up to 200 Ap power, DC –100 kHz bandwidth, and controlled-current or controlled-voltage modes of operation. The 7796 works best into loads of 0.5 ohms or less. For greater voltage or current (up to 800 Ap) units can be combined in parallel or series.
Typically used when large currents are needed to drive very low impedances for long periods of time. Often used as a battery substitute for transient immunity testing requiring a battery as specified in EMC Test Standards for military, aviation and the automotive industries.
Features:
- Stable when driving a wide range of resistive, inductive or capacitive loads
- 60A continuous at 13.8 VDC
- 200A in-rush current capability
- 150 kHz small signal bandwidth
- ±95 VDC capable
- 41 V/μS slew rate