Keysight N6781A Source/Measure Unit for Battery Drain Analysis, 2-Quadrant, 20 V, 1 A or 6 V, 3 A, 20 W

Key Specifications

Output Ratings:

  • Voltage: Up to 20 V
  • Current: Up to ±3 A
  • Power: 20 W

Programming Accuracy (at 23°C ± 5°C after 30 minute warm-up. Applies from min. to max. program):

  • Voltage, 20 V range: 0.025% + 1.8 mV
  • Voltage, 6 V range: 0.025% + 600 µV
  • Current, 3 A and 1 A ranges: 0.04% + 300 µA
  • Current, 300 mA range: 0.03% + 150 µA

Transient Response:

  • < 30 mV of droop in response to 0.15A / µs current transients

Measurement Accuracy (at 23°C ± 5°C):

  • Voltage, 20 V range: 0.025% + 1.2 mV*
  • Current, 3 A range: 0.03% + 250 µA*
  • Current, 100 mA range: 0.025% + 10 µA*
  • Current, 10 µA range: 0.025% + 8 nA

Documents and Software Solutions:

Product Number:

N6781A

Manufacturer:

Keysight Technologies

Quantity:

Total
Unit price
Base Product
Availability:
Typically on stock
Expected Delivery Time:
4-5 days from Keysight Inventory

*Supports Seamless Measurement Ranging

The Keysight N6781A is a source/measure unit (SMU) designed specifically for the task of battery drain analysis. Whether the device-under-test (DUT) is an e-Book reader, MP3 player, mobile phone, or pacemaker, the N6781A’s seamless measurement ranging, programmable output resistance, and auxiliary DVM combine to be the best set of advanced features on the market for battery drain analysis. When used with the 14585A Control and Analysis software, the N6781A becomes an even more powerful battery drain analysis solution, offering additional insights into your measurements. Learn more about the 14585A Control and Analysis software.

See Measurement Solution Example: Battery Current Drain Test

*Keysight patented feature: Seamless Measurement Ranging

Seamless measurement ranging eliminates the challenges of measuring dynamic currents. With seamless measurement ranging, engineers can precisely measure dynamic currents without any glit ches or disruptions to the measurement. As the current drawn by the DUT changes, the SMU automatically and instantaneously detects which current measurement ranges will return the most precise measurement and changes to that range seamlessly. When combined with the SMU´s built-in 18-bit digitizer, seamless measurement ranging enables unprecedented effective vertical resolution of 28-bits. This provides unrivaled productivity gains and insights into power consumption by enabling engineers to see the complete current waveform they have never seen before, from nA to A, in one pass and one picture.

Battery Drain Video: Seamless Measurement Ranging on the N6781A

Other features and benefits of the N6781A:

  • Glitch-free sourcing and measurement ? change output and measurement ranges without any glitches
  • 2-quadrant operation ? perform as a voltage or current source or as a CV or CC electronic load
  • Four current measurement ranges ? precisely capture the current levels of the DUT during different modes of operation
  • Excellent transient response ? keep voltage or current stable during high-speed load changes
  • Fast modulation of DC ? create waveforms up to 100 kHz to stimulate or load down the DUT
  • High-speed digitized measurements ? capture/view the power consumption of the DUT up to ever y 5 µs with built-in 200 kHz digitizer
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

*Supports Seamless Measurement Ranging

The Keysight N6781A is a source/measure unit (SMU) designed specifically for the task of battery drain analysis. Whether the device-under-test (DUT) is an e-Book reader, MP3 player, mobile phone, or pacemaker, the N6781A’s seamless measurement ranging, programmable output resistance, and auxiliary DVM combine to be the best set of advanced features on the market for battery drain analysis. When used with the 14585A Control and Analysis software, the N6781A becomes an even more powerful battery drain analysis solution, offering additional insights into your measurements. Learn more about the 14585A Control and Analysis software.

See Measurement Solution Example: Battery Current Drain Test

*Keysight patented feature: Seamless Measurement Ranging

Seamless measurement ranging eliminates the challenges of measuring dynamic currents. With seamless measurement ranging, engineers can precisely measure dynamic currents without any glit ches or disruptions to the measurement. As the current drawn by the DUT changes, the SMU automatically and instantaneously detects which current measurement ranges will return the most precise measurement and changes to that range seamlessly. When combined with the SMU´s built-in 18-bit digitizer, seamless measurement ranging enables unprecedented effective vertical resolution of 28-bits. This provides unrivaled productivity gains and insights into power consumption by enabling engineers to see the complete current waveform they have never seen before, from nA to A, in one pass and one picture.

Battery Drain Video: Seamless Measurement Ranging on the N6781A

Other features and benefits of the N6781A:

  • Glitch-free sourcing and measurement ? change output and measurement ranges without any glitches
  • 2-quadrant operation ? perform as a voltage or current source or as a CV or CC electronic load
  • Four current measurement ranges ? precisely capture the current levels of the DUT during different modes of operation
  • Excellent transient response ? keep voltage or current stable during high-speed load changes
  • Fast modulation of DC ? create waveforms up to 100 kHz to stimulate or load down the DUT
  • High-speed digitized measurements ? capture/view the power consumption of the DUT up to ever y 5 µs with built-in 200 kHz digitizer
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha