We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

Micsig RCP300XS Rogowski AC Current Probe (10 Hz - 30 MHz, 300 Apk)

Key Features and Benefits

Micsig RCP series Rogowski current probe measures AC currents up to 6000 Apk, max. bandwidth up to 30 MHz, withstand voltage is up to 1kVrms, nearly zero insertion impedance, greatly minimized the interference to the DUT.

A 1.6mm thin, flexible, clip-around Rogowski coil allow user easily pass through pin leg of TO-220 semiconductor devices. With 2% accuracy (typical) , accurately measures high-frequency and high-current signals like double-pulse dynamic test, monitor semiconductor switch current.

  • Bandwidth: 10Hz - 30 MHz
  • Peak current: 300 Apk
  • Output sensitivity: 20mV/A (50X)
  • Accuracy (typical): 2%
  • Peak di/dt: 20 kA/μs

Further information:

Product Number:

Mic-RCP300XS

Manufacturer:

Micsig

Quantity:

Total
Unit price
Base Product
Availability:
Call or email for delivery time

BNC interface Standard

BNC interface to use on any oscilloscope, most compact flexible design easily solved the hard-to reach part issue, coil diameter support customzied made to meet more test requirements.

Smallest coil cross-section

The cross-sectional diameter of the coil is only 1.6mm, allow engineers measure current in most difficult-to-reach parts of the circuit, such as narrow pin spacing chip like TO-220, TO-47.

Measure the Id current of MOSFET

The RCP has excellent high-frequency measurement capabilities, easily handles high-speed signals and rapidly changing current waveforms, helping to observe high-frequency harmonic components when measuring the Id current of MOSFETs. (as shown the oscillation section).

Applications

  • Measuring current in motor drives and in particular power quality measurements in VSD, UPS or SMPS circuits
  • Double-pulse testing to measure the pin currents of MOSFET and IGBT chips made of materials such as SiC and GaN
  • Measurement of load current and high-order harmonic current in power electronics
  • Measuring high frequency sinusoidal, pulsed or transient currents
  • Measuring AC currents in 3-phase supply system
  • Measuring the power consumption in semiconductors
  • Measurement of 50/60Hz power frequency current
  • Power converter development and diagnostics
ModelRCP60XSRCP300XSRCP600XSRCP1200XSRCP3000XSRCP6000XS
Bandwidth85 Hz - 30 MHz10 Hz - 30 MHz10 Hz - 30 MHz12 Hz - 30 MHz3 Hz - 30 MHz2 Hz - 30 MHz
Peak current60 Apk300 Apk600 Apk1200 Apk3000 Apk6000 Apk
Output sensitivity100 mV/A (10x)20 mV/A (50X)10 mV/A (100X)5 mV/A (200X)2 mV/A (500X)1 mV/A (1000X)
Accuracy (typical)2%2%2%2%2%2%
Peak di/dt4kA/μs20 KA/μs40 KA/μs70 KA/μs70 KA/μs70 KA/μs
Droop65%/ms9%/ms6%/ms3%/ms2%/ms2%/ms
Noise 
Peak coil isolation voltageAC 1 kVrms (1min) (50 Hz/60 Hz) (Rogowski coil part only)AC 1 kVrms (1min) (50 Hz/60 Hz) (Rogowski coil part only)AC 1 kVrms (1min) (50 Hz/60 Hz) (Rogowski coil part only)AC 1 kVrms (1min) (50 Hz/60 Hz) (Rogowski coil part only)AC 1 kVrms (1min) (50 Hz/60 Hz) (Rogowski coil part only)AC 1 kVrms (1min) (50 Hz/60 Hz) (Rogowski coil part only)
Cable length1.5m from integrator to coil, customizable1.5m from integrator to coil, customizable1.5m from integrator to coil, customizable1.5m from integrator to coil, customizable1.5m from integrator to coil, customizable1.5m from integrator to coil, customizable
Rogowski coil inner diameter25 mm, measures wires within 20 mm in diameter, customizable25 mm, measures wires within 20 mm in diameter, customizable25 mm, measures wires within 20 mm in diameter, customizable25 mm, measures wires within 20 mm in diameter, customizable25 mm, measures wires within 20 mm in diameter, customizable25 mm, measures wires within 20 mm in diameter, customizable
Rogowski coil circumference80 mm, customizable80 mm, customizable80 mm, customizable80 mm, customizable80 mm, customizable80 mm, customizable
Coil cross-section diameter1.6 mm1.6 mm1.6 mm1.6 mm1.6 mm1.6 mm
Output impedance1 MΩ1 MΩ1 MΩ1 MΩ1 MΩ1 MΩ
InterfaceUniversal BNCUniversal BNCUniversal BNCUniversal BNCUniversal BNCUniversal BNC
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

BNC interface Standard

BNC interface to use on any oscilloscope, most compact flexible design easily solved the hard-to reach part issue, coil diameter support customzied made to meet more test requirements.

Smallest coil cross-section

The cross-sectional diameter of the coil is only 1.6mm, allow engineers measure current in most difficult-to-reach parts of the circuit, such as narrow pin spacing chip like TO-220, TO-47.

Measure the Id current of MOSFET

The RCP has excellent high-frequency measurement capabilities, easily handles high-speed signals and rapidly changing current waveforms, helping to observe high-frequency harmonic components when measuring the Id current of MOSFETs. (as shown the oscillation section).

Applications

  • Measuring current in motor drives and in particular power quality measurements in VSD, UPS or SMPS circuits
  • Double-pulse testing to measure the pin currents of MOSFET and IGBT chips made of materials such as SiC and GaN
  • Measurement of load current and high-order harmonic current in power electronics
  • Measuring high frequency sinusoidal, pulsed or transient currents
  • Measuring AC currents in 3-phase supply system
  • Measuring the power consumption in semiconductors
  • Measurement of 50/60Hz power frequency current
  • Power converter development and diagnostics
ModelRCP60XSRCP300XSRCP600XSRCP1200XSRCP3000XSRCP6000XS
Bandwidth85 Hz - 30 MHz10 Hz - 30 MHz10 Hz - 30 MHz12 Hz - 30 MHz3 Hz - 30 MHz2 Hz - 30 MHz
Peak current60 Apk300 Apk600 Apk1200 Apk3000 Apk6000 Apk
Output sensitivity100 mV/A (10x)20 mV/A (50X)10 mV/A (100X)5 mV/A (200X)2 mV/A (500X)1 mV/A (1000X)
Accuracy (typical)2%2%2%2%2%2%
Peak di/dt4kA/μs20 KA/μs40 KA/μs70 KA/μs70 KA/μs70 KA/μs
Droop65%/ms9%/ms6%/ms3%/ms2%/ms2%/ms
Noise 
Peak coil isolation voltageAC 1 kVrms (1min) (50 Hz/60 Hz) (Rogowski coil part only)AC 1 kVrms (1min) (50 Hz/60 Hz) (Rogowski coil part only)AC 1 kVrms (1min) (50 Hz/60 Hz) (Rogowski coil part only)AC 1 kVrms (1min) (50 Hz/60 Hz) (Rogowski coil part only)AC 1 kVrms (1min) (50 Hz/60 Hz) (Rogowski coil part only)AC 1 kVrms (1min) (50 Hz/60 Hz) (Rogowski coil part only)
Cable length1.5m from integrator to coil, customizable1.5m from integrator to coil, customizable1.5m from integrator to coil, customizable1.5m from integrator to coil, customizable1.5m from integrator to coil, customizable1.5m from integrator to coil, customizable
Rogowski coil inner diameter25 mm, measures wires within 20 mm in diameter, customizable25 mm, measures wires within 20 mm in diameter, customizable25 mm, measures wires within 20 mm in diameter, customizable25 mm, measures wires within 20 mm in diameter, customizable25 mm, measures wires within 20 mm in diameter, customizable25 mm, measures wires within 20 mm in diameter, customizable
Rogowski coil circumference80 mm, customizable80 mm, customizable80 mm, customizable80 mm, customizable80 mm, customizable80 mm, customizable
Coil cross-section diameter1.6 mm1.6 mm1.6 mm1.6 mm1.6 mm1.6 mm
Output impedance1 MΩ1 MΩ1 MΩ1 MΩ1 MΩ1 MΩ
InterfaceUniversal BNCUniversal BNCUniversal BNCUniversal BNCUniversal BNCUniversal BNC