Micsig MOIP500P SigOFIT Optical-fiber Isolated Probe 500 MHz Bandwidth
Key Features and Benefits
- Up to 1 GHz bandwidth
- 180 dB CMRR at DC
- Over 108 dB CMRR at 1 GHz
- 85 kVpk Common mode voltage range
- Up to ±6250 V differential input voltage range
- 1% DC gain accuracy
- Auto calibration in 1 second
- Support all BNC-type oscilloscopes
Key Applications:
- Design of motor drive, power converter
- Design of GaN, SiC, Half/Full bridge devices
- Design of inverter, UPS and switching power supply
- High voltage high bandwidth safety test
- Power device evaluation
- Current shunt measurements
- EMI & ESD troubleshooting
- Floating measurements
Further information:
With Micsig's exclusive SigOFIT™ optical isolation technology, the SigOFIT probe delivers 180dB CMRR at DC, 128dB at 100MHz, up to 108dB at 1GHz, able to test differential mode signals from ±0.01V to ±6250V when using with attenuators, present true signal you’ve never seen. It's the most ideal method for isolated probe technology.
Present True Signal
SigOFIT probe has highest common mode rejection ratio, or CMRR, up to 128dB at 100MHz, over 100dB at 1GHz. It's the ultimate referee of signal fidelity measured by other voltage probes.
Best Probe for GaN and SiC
Third-Gen Semiconductor device like SiC and GaN can switch high voltages in a few nanoseconds, containing very high-energy high-frequency harmonics. SigOFIT probe perfectly suppress oscillation caused by high-frequency common-mode noise by employing high-quality coaxial attenuating tips and industry standard MMCX & MCX connectors, unveils real signal for every engineers.
Highest Accuracy
As the ultimate referee of signal fidelity, SigOFIT optical-fiber isolated probe delivers highest test accuracy. It has excellent amplitude-frequency characteristics, DC gain accuracy ≤1%, while noise ≤ 0.45mVrms. Zero drift<0.1% (works 5 mins later), gain drift also <1%.
Real Optical Isolation Technology
Lasers transmit signals + Power over fiber (no batteries needed, the power supply is more pure), realizes continuous test for 365 days.
With Micsig's exclusive SigOFIT™ optical isolation technology, the SigOFIT probe delivers 180dB CMRR at DC, 128dB at 100MHz, up to 108dB at 1GHz, able to test differential mode signals from ±0.01V to ±6250V when using with attenuators, present true signal you’ve never seen. It's the most ideal method for isolated probe technology.
Present True Signal
SigOFIT probe has highest common mode rejection ratio, or CMRR, up to 128dB at 100MHz, over 100dB at 1GHz. It's the ultimate referee of signal fidelity measured by other voltage probes.
Best Probe for GaN and SiC
Third-Gen Semiconductor device like SiC and GaN can switch high voltages in a few nanoseconds, containing very high-energy high-frequency harmonics. SigOFIT probe perfectly suppress oscillation caused by high-frequency common-mode noise by employing high-quality coaxial attenuating tips and industry standard MMCX & MCX connectors, unveils real signal for every engineers.
Highest Accuracy
As the ultimate referee of signal fidelity, SigOFIT optical-fiber isolated probe delivers highest test accuracy. It has excellent amplitude-frequency characteristics, DC gain accuracy ≤1%, while noise ≤ 0.45mVrms. Zero drift<0.1% (works 5 mins later), gain drift also <1%.
Real Optical Isolation Technology
Lasers transmit signals + Power over fiber (no batteries needed, the power supply is more pure), realizes continuous test for 365 days.