ITECH IT9121 AC/DC Power Meter 600 Vrms, 20 Arms
AC/DC Power meter
Specifications:
Voltage Range:
- Crest factor 3: 5 V, 30 V, 60 V,150 V,300 V, 600 V
- Crest factor 6: 7.5 V, 15 V, 30 V, 75 V, 150 V, 300 V
Direct Current Range:
- Crest factor 3: 5 mA, 10 mA, 20 mA, 50 mA, 100 mA, 200 mA, 0.5 A, 1 A, 2 A, 5 A, 10 A, 20 A
- Crest factor 5: 2.5 mA, 5 mA, 10 mA, 25 mA, 50 mA, 100 mA, 250 mA, 0.5 A, 1 A, 2.5 A, 5 A, 10 A
Sensor input EX1:
- Crest factor 3: 2.5 V, 5 V, 10 V
- Crest factor 6: 1.25 V, 2.5 V, 5 V
Sensor input EX2:
- Crest factor 3: 50 mV, 100 mV, 200 mV, 500 mV, 1 V, 2 V
- Crest factor 6: 25 mV, 50 mV, 100 mV, 250 mV, 500 mV, 1 V
Accuracy Voltage and Current:
- DC: ± (0.1% of reading + 0.2% of range)
- 0.5 Hz ≤ f ≤ 45 Hz: ± (0.1 % of reading + 0.2 % of range)
- 45 Hz ≤ f ≤ 66 Hz: ± (0.1 % of reading + 0.2 % of range)
- 66 Hz ≤ f ≤ 1 kHz: ± (0.1 % of reading + 0.2 % of range)
- 1 kHz ≤ f ≤ 10 kHz: ± (0.1 % of reading + 0.2 % of range) ± (0.07 *f) % of reading + 0.3% of range)
- 10 kHz ≤ f ≤ 100 kHz: ± (0.5 % of reading + 0.5 % of range) ± (0.04 x (f-10))% of reading
Accuracy Active Power:
- DC: (0.1 % of reading + 0.2 % of range)
- 0.5 Hz ≤ f ≤ 45 Hz: ± (0.3 % of reading + 0.2 % of range)
- 45 Hz ≤ f ≤ 66 Hz: ± (0.1 % of reading + 0.1 % of range)
- 66 Hz ≤ f ≤ 1kHz: ± (0.2 % of reading + 0.2 % of range)
- 1 kHz ≤ f ≤ 10 kHz: ± (0.1 % of reading + 0.3 % of range) ± [{0.067x(f-1)}% of reading]
- 10 kHz ≤ f ≤ 100 kHz: ± (0.5 % of reading + 0.5 % of range) ± [{0.09x(f-10)}% of reading]
Accuracy Frequency:
- ± (0.06 % of reading)
- Input bandwidth: DC, 0.5 Hz - 1 MHz
A/D converter:
- Simultaneous conversion voltage an current inputs
- Resolution: 18-bit
- 100 kHz bandwidth
- Maximum conversion rate: 10 μs
- Continuous maximum Common-mode voltage: 600 Vrms, CAT ?
Power measurements:
- Voltage
- Current
- Active power [W]
- Reactive power [var]
- Apparent power [VA]
- Power factor
- Phase difference (°)
- Frequency (Hz)
- Max/min of voltage (V)
- Max/min of current (A)
- Crest factor
- Integration
Feature set:
- Oscilloscope function shows voltage and current
- Simultaneous measurement
- 4.3-inch color LCD (TFT)
- Harmonic measurements (50th harmonic)
- Barchart display of harmonics
- Current transducer inputs
Connectivity:
- LAN, RS-232 and USB
- SCPI programming
Documents and Software Solutions:
Availability:
Typically on stock
Quick Delivery
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Description
Reviews
Query on the Item
Do you have any questions on this item?