We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

Hioki-IM3536 LCR METER, DC, or 4 Hz to 8 MHz

General-Purpose LCR Meters with Measurement Frequency from DC, 4 Hz to 8 MHz

Key Features and Functions

  • ±0.05% accuracy with wide measurement range (DC, 1mHz to 200kHz, 5mV to 5V, 10uA to 50mA)
  • Non-stop testing over mixed measurement conditions such as C-D and ESR at 10 times the speed of previous models
  • Built-in low impedance high precision mode effective for testing low inductance or the ESR of aluminum electrolysis capacitance
  • Dedicated modes for measuring transformer winding ratio, mutual inductance and temperature compensated DCR
  • Frequency sweep testing (IM3533-01 only)
  • 2m/4m cable setting in addition to the standard 0m/1m
  • Touch screen with intuitive operation

Documents and Software:

Product Number:

Hioki-IM3536

Manufacturer:

Hioki

Quantity:

Total
Unit price
Base Product
Availability:
Typically on stock
Quick Delivery

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The IM3536 raises the industry standard for general-purpose LCR meters by offering a wide DC and 4Hz to 8MHz (up to 10MHz special order available) testing frequency while delivering 0.05% accuracy, ideal for evaluating the characteristics of next generation electronic components, including power supply inductors thanks to the instrument’s maximum measurement frequency of 8MHz. (up to 10MHz special order available)

Key Specifications:

  • Measurement modes: LCR (Measurement with single condition), Continuous testing (Continuous measurement under saved conditions)
  • Measurement parameters: Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ), σ, ε
  • Measurement range: 100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z)
  • Display range:
    • Z: 0.00 m to 9.99999 GΩ, Y: 0.000 n to 9.99999 GS, θ: ± (0.000° to 180.000°), Q: ± (0.00 to 9999.99), Rdc: ± (0.00 m to 9.99999 GΩ),
    • D: ± (0.00000 to 9.99999), Δ%: ± (0.000 % to 999.999 %), or other
  • Basic accuracy: Z ±0.05% rdg. θ: ±0.03° (representative value, Measurable range: 1 mΩ to 200 MΩ)
  • Measurement frequency: 4 Hz to 8 MHz (5 digits setting resolution, minimum resolution 10 mHz)
  • Measurement signal level:
    • [Normal mode: V mode/CV mode]
    • 4 Hz to 1.0000 MHz: 10 mV to 5 Vrms (maximum 50 mArms)
    • 1.0001 MHz to 8 MHz: 10 mV to 1 Vrms (maximum 10mArms)
    • [Low impedance high accuracy mode: V mode/CV mode]
    • 4 Hz to 1.0000 MHz: 10 mV to 1 Vrms (maximum 100 mArms)
    • [Normal mode: CC mode]
    • 4 Hz to 1.0000 MHz: 10 μA to 50 mArms (maximum 5 Vrms)
    • 1.0001 MHz to 8 MHz: 10 μA to 10 mArms (maximum 1 Vrms)
    • [Low impedance high accuracy mode: CC mode]
    • 4 Hz to 1.0000 MHz: 10 μA to 100 mArms (maximum 1 Vrms)
    • [DC resistance measurement]
    • Measurement signal level: Fixed at 1 V
  • DC bias measurement: Generating range: DC voltage 0 V to 2.50 V (10 mV resolution)
  • In low Z high accuracy mode: 0 V to 1 V (10 mV resolution)
  • Output impedance: Normal mode: 100 Ω, Low impedance high accuracy mode: 10 Ω
  • Display: 5.7-inch color TFT with touch panel
  • Functions: Comparator, BIN measurement (10 categories for 2 measurement parameters), Trigger function, Open/short compensation, Contact check, Panel loading/saving, Memory function
  • Interfaces: EXT. I/O( HANDLER) ,USB, USB flash drive, LAN, GP-IB, RS-232C, BCD
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The IM3536 raises the industry standard for general-purpose LCR meters by offering a wide DC and 4Hz to 8MHz (up to 10MHz special order available) testing frequency while delivering 0.05% accuracy, ideal for evaluating the characteristics of next generation electronic components, including power supply inductors thanks to the instrument’s maximum measurement frequency of 8MHz. (up to 10MHz special order available)

Key Specifications:

  • Measurement modes: LCR (Measurement with single condition), Continuous testing (Continuous measurement under saved conditions)
  • Measurement parameters: Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ), σ, ε
  • Measurement range: 100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z)
  • Display range:
    • Z: 0.00 m to 9.99999 GΩ, Y: 0.000 n to 9.99999 GS, θ: ± (0.000° to 180.000°), Q: ± (0.00 to 9999.99), Rdc: ± (0.00 m to 9.99999 GΩ),
    • D: ± (0.00000 to 9.99999), Δ%: ± (0.000 % to 999.999 %), or other
  • Basic accuracy: Z ±0.05% rdg. θ: ±0.03° (representative value, Measurable range: 1 mΩ to 200 MΩ)
  • Measurement frequency: 4 Hz to 8 MHz (5 digits setting resolution, minimum resolution 10 mHz)
  • Measurement signal level:
    • [Normal mode: V mode/CV mode]
    • 4 Hz to 1.0000 MHz: 10 mV to 5 Vrms (maximum 50 mArms)
    • 1.0001 MHz to 8 MHz: 10 mV to 1 Vrms (maximum 10mArms)
    • [Low impedance high accuracy mode: V mode/CV mode]
    • 4 Hz to 1.0000 MHz: 10 mV to 1 Vrms (maximum 100 mArms)
    • [Normal mode: CC mode]
    • 4 Hz to 1.0000 MHz: 10 μA to 50 mArms (maximum 5 Vrms)
    • 1.0001 MHz to 8 MHz: 10 μA to 10 mArms (maximum 1 Vrms)
    • [Low impedance high accuracy mode: CC mode]
    • 4 Hz to 1.0000 MHz: 10 μA to 100 mArms (maximum 1 Vrms)
    • [DC resistance measurement]
    • Measurement signal level: Fixed at 1 V
  • DC bias measurement: Generating range: DC voltage 0 V to 2.50 V (10 mV resolution)
  • In low Z high accuracy mode: 0 V to 1 V (10 mV resolution)
  • Output impedance: Normal mode: 100 Ω, Low impedance high accuracy mode: 10 Ω
  • Display: 5.7-inch color TFT with touch panel
  • Functions: Comparator, BIN measurement (10 categories for 2 measurement parameters), Trigger function, Open/short compensation, Contact check, Panel loading/saving, Memory function
  • Interfaces: EXT. I/O( HANDLER) ,USB, USB flash drive, LAN, GP-IB, RS-232C, BCD
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha