Key Features and Functions
- ±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
- Measure up to 10 A with direct input
- Dual display lets you check voltage and frequency simultaneously
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- USB communications function supports PC measurements (optional)
- Broad -25°C to 65°C (-13°F to 149°F) operating temperature range
Documents and Software:
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4256 is a digital multimeter designed to deliver maximum functionality for use in a wide range of settings.
Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year
DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
- DC Voltage range:
- 600.0 mV to 1000 V, 5 ranges
- Basic accuracy: ±0.3 % rdg. ±3 dgt.
- AC Voltage range:
- 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
- Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
- AUTO AC/DCV: Yes
- Resistance range: 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt.
- DC Current range:
- 60.00 mA to 10.00 A, 4 ranges,
- Basic accuracy: ±0.9 % rdg. ±3 dgt.
- AC Current range:
- 600.0 mA to 10.00 A, 3 ranges,
- Basic accuracy 40 - 500 Hz : ±1.4 % rdg. ±3 dgt.
- (True RMS, crest factor 3, 40 Hz to 1 kHz)
- AC Current range, (use with Clamp on probes):
- 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
- Voltage detection, (50/60 Hz): Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
- Capacitance range: 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt.
- Frequency range:
- 99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage and current),
- Basic accuracy: ±0.1 % rdg. ±1 dgt.
- Continuity check:
- Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED),
- [OFF]: 245 Ω or more, Response time: 0.5 ms or more
- Diode test: Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less,
- Threshold of forward voltage: 0.15 V to 1.5 V
- Other functions:
- Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option)
- Display: Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display refresh rates: 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
- Power supply: LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)
- Dimensions and mass:
- 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
- 390 g (13.8 oz) (including batteries and holster)
- Accessories: Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4256 is a digital multimeter designed to deliver maximum functionality for use in a wide range of settings.
Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year
DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
- DC Voltage range:
- 600.0 mV to 1000 V, 5 ranges
- Basic accuracy: ±0.3 % rdg. ±3 dgt.
- AC Voltage range:
- 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
- Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
- AUTO AC/DCV: Yes
- Resistance range: 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt.
- DC Current range:
- 60.00 mA to 10.00 A, 4 ranges,
- Basic accuracy: ±0.9 % rdg. ±3 dgt.
- AC Current range:
- 600.0 mA to 10.00 A, 3 ranges,
- Basic accuracy 40 - 500 Hz : ±1.4 % rdg. ±3 dgt.
- (True RMS, crest factor 3, 40 Hz to 1 kHz)
- AC Current range, (use with Clamp on probes):
- 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
- Voltage detection, (50/60 Hz): Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
- Capacitance range: 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt.
- Frequency range:
- 99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage and current),
- Basic accuracy: ±0.1 % rdg. ±1 dgt.
- Continuity check:
- Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED),
- [OFF]: 245 Ω or more, Response time: 0.5 ms or more
- Diode test: Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less,
- Threshold of forward voltage: 0.15 V to 1.5 V
- Other functions:
- Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option)
- Display: Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display refresh rates: 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
- Power supply: LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)
- Dimensions and mass:
- 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
- 390 g (13.8 oz) (including batteries and holster)
- Accessories: Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4