Hioki-DT4254 DIGITAL MULTIMETER
Digital Multimeter for Efficiently Maintaining Power Equipment, PV and Megasolar Devices
Key Features and Functions
- The voltage measurement model, which is ideal for solar power system and power equipment management, measures up to 1700 V DC during open voltage inspections (DT4254)
- Prevents accidents with clamp-on sensor-based current measurement (DT4254, DT4255)
- Voltage detection function (DT4254, DT4255)
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Broad -25°C (-13°F) to 65°C (149°F) operating temperature range (DT4254, DT4255)
- Dual display lets you check voltage and frequency simultaneously
Documents and Software:
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4254 is a voltage measurement only model designed for measuring photovoltaic modules and other high-voltage targets up to 1700 V DC
Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year
Regarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information. *1 Your instrument can be used to measure voltages in excess of 1000 V DC if and only if both of the following conditions are satisfied: 1. The circuit under measurement is isolated from the commercial power grid. 2. The circuit under measurement is isolated from ground.
- DC Voltage range:
- 600.0 mV to 1700 V (*1)
- 5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt.
- AC Voltage range:
- 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
- Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
- AUTO AC/DCV: Yes
- Resistance range: N/A
- DC Current range: N/A
- From 4 to 20mA Percentage conversion display: N/A
- AC Current range (use with Clamp on probes): N/A
- Temperature (thermocouples): N/A
- Voltage detection: Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
- Capacitance range: N/A
- Frequency range: 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
- Basic accuracy: ±0.1 % rdg. ±1 dgt.
- Continuity check: N/A
- Diode test: N/A
- Other functions: Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option)
- Display: Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display refresh rates: 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s)
- Power supply: LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)
- Dimensions and mass:
- 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
- 390 g (13.8 oz) (including batteries and holster)
- Accessories: Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4254 is a voltage measurement only model designed for measuring photovoltaic modules and other high-voltage targets up to 1700 V DC
Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year
Regarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information. *1 Your instrument can be used to measure voltages in excess of 1000 V DC if and only if both of the following conditions are satisfied: 1. The circuit under measurement is isolated from the commercial power grid. 2. The circuit under measurement is isolated from ground.
- DC Voltage range:
- 600.0 mV to 1700 V (*1)
- 5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt.
- AC Voltage range:
- 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
- Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
- AUTO AC/DCV: Yes
- Resistance range: N/A
- DC Current range: N/A
- From 4 to 20mA Percentage conversion display: N/A
- AC Current range (use with Clamp on probes): N/A
- Temperature (thermocouples): N/A
- Voltage detection: Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
- Capacitance range: N/A
- Frequency range: 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
- Basic accuracy: ±0.1 % rdg. ±1 dgt.
- Continuity check: N/A
- Diode test: N/A
- Other functions: Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option)
- Display: Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display refresh rates: 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s)
- Power supply: LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)
- Dimensions and mass:
- 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
- 390 g (13.8 oz) (including batteries and holster)
- Accessories: Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4