Hioki-BT3554-92 BATTERY TESTER, with angled pin type lead L2020, bundled withZ3210 wireless dongle
Streamline UPS and lead-acid battery diagnostics with measurement and recording guidance
Key Features and Functions
- Battery measurement can be performed while the battery is connected to its host device, without taking it offline
- Measure and save data in as fast as 2 seconds, a 60% improvement from the legacy 3554
- Instantaneously diagnose battery degradation (PASS, WARNING, FAIL) by measuring internal resistance and voltage*1
- Noise reduction technology improves noise resistance
- Screen and audio*2 guidance simplifies measurement
- Measurement data is linked to site information and saved, reducing management man-hours
- A variety of measurement data can be centrally managed using Hioki’s GENNECT Cross app*3
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- New protector delivers better ergonomic hold and durability in the field.
Documents and Software:
Hioki portable battery testers support the maintenance of UPS and storage batteries critical to the life support of all businesses. The BT3554-50 battery internal resistance tester sets the standard for assessing the deterioration and remaining life of UPS and other lead-acid batteries by giving a complete diagnosis via battery resistance testing. The specially designed L2020 Pin Type Lead further improves testing efficiency with an L-shaped tip that lets you reach deep into the battery racks to completely probe the terminals.
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
- Resistance measurement range: 3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges
- Accuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt)
- Testing source frequency: 1 kHz ±30 Hz
- With function for avoiding noise frequency enabled: 1 kHz ±80 Hz
- Testing current: 160 mA (3m/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range)
- Open terminal Voltage: 5 V peak
- Voltage measurement range: ± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08 % rdg ±6 dgt
- Temperature measurement accuracy:
- Measurement range: -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F), Measurement accuracy*: ±1.0°C (±1.8°F)
- * When using the Clip Type Lead with Temperature Sensor 9460.
- * When using the Temperature Probe 9451, add ±0.5°C (±0.9°F) (cable length: 1.5 m [59.1']).
- * When using the Temperature Probe 9451S, add ±0.5°C (±0.9°F) (cable length: 0.1 m [3.94']).
- BT3554-50 standalone accuracy with simulated input: ±0.5°C (±0.9°F)
- Absolute max. input voltage: 60 V DC max. (No AC input)
- Measurement time: 100 ms
- Response time: Approx. 1.6 sec.
- Comparator:
- Compares measured values with set threshold values to make judgments and reports them to the user.
- Judgment notification method: Results are displayed as shown below (segment) and beeping tones sound
- When the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL
- When the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL
- If the judgment result is WARNING or FAIL, the audio tone is accompanied by a red backlight.
- User-selectable voltage judgment method: ABS (absolute value judgment), POL (polarity judgment )
- Savable settings: 200 tables
- Memory functionality:
- Operation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units)
- Saved data: Saved measurement data is linked to profile information.
- Measurement data: Data can be saved, loaded, and deleted by operating the instrument.
- -1. Date and time
- -2. Resistance value, voltage value, and temperature
- -3. Comparator threshold value and judgment result
- Profile information: Profile information can be saved, loaded, and deleted using a supported application (GENNECT Cross or GENNECT One).
- -1. Profile numbers: 1 to 100 (Data (2), (3), and (4) below are saved for each profile number)
- -2. Location: User-defined comment such as location of UPS
- -3. Device information: User-defined comment such as UPS management number
- -4. Battery number: 1 to 500 (start number, end number)
- Measurement Navigator:
- Operation: Announces the next battery number to be measured via a screen display and audio guidance.
- Audio output is generated by a connected mobile device when using the Z3210 and a supported application (GENNECT Cross).
- Preparations: Profile information that's been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument.
- Communication interface: USB
- Bluetooth® wireless communications (when Z3210 installed)
- Other functions: Temperature measurement (-10.0 to 60.0 °C), Zero-adjustment, Hold, Auto-hold, Auto-memory, Auto-power-save, Clock
- Power supply:
- LR6 (AA) Alkaline dry battery ×8
- Continuous operating time: About 8.3 hr. (without Z3210 installed), About 8.2 hr. (with Z3210 installed and wireless communications active)
- Dimensions and mass:
- 199 mm (7.83 in)W × 132 mm (5.20 in)H × 60.6 mm (2.39 in)D (with protector), 960 g (33.9 oz) (including batteries and protector)
- Accessories:
- Carrying Case C1014 ×1, Protector Z5041 ×1, Fuse Set Z5050 ×1, 0 Adj Board ×1, Neck strap ×1, USB cable ×1, Application software CD (GENNECT One) ×1, AA alkaline battery (LR6) ×8, User Manual ×1
Hioki portable battery testers support the maintenance of UPS and storage batteries critical to the life support of all businesses. The BT3554-50 battery internal resistance tester sets the standard for assessing the deterioration and remaining life of UPS and other lead-acid batteries by giving a complete diagnosis via battery resistance testing. The specially designed L2020 Pin Type Lead further improves testing efficiency with an L-shaped tip that lets you reach deep into the battery racks to completely probe the terminals.
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
- Resistance measurement range: 3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges
- Accuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt)
- Testing source frequency: 1 kHz ±30 Hz
- With function for avoiding noise frequency enabled: 1 kHz ±80 Hz
- Testing current: 160 mA (3m/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range)
- Open terminal Voltage: 5 V peak
- Voltage measurement range: ± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08 % rdg ±6 dgt
- Temperature measurement accuracy:
- Measurement range: -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F), Measurement accuracy*: ±1.0°C (±1.8°F)
- * When using the Clip Type Lead with Temperature Sensor 9460.
- * When using the Temperature Probe 9451, add ±0.5°C (±0.9°F) (cable length: 1.5 m [59.1']).
- * When using the Temperature Probe 9451S, add ±0.5°C (±0.9°F) (cable length: 0.1 m [3.94']).
- BT3554-50 standalone accuracy with simulated input: ±0.5°C (±0.9°F)
- Absolute max. input voltage: 60 V DC max. (No AC input)
- Measurement time: 100 ms
- Response time: Approx. 1.6 sec.
- Comparator:
- Compares measured values with set threshold values to make judgments and reports them to the user.
- Judgment notification method: Results are displayed as shown below (segment) and beeping tones sound
- When the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL
- When the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL
- If the judgment result is WARNING or FAIL, the audio tone is accompanied by a red backlight.
- User-selectable voltage judgment method: ABS (absolute value judgment), POL (polarity judgment )
- Savable settings: 200 tables
- Memory functionality:
- Operation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units)
- Saved data: Saved measurement data is linked to profile information.
- Measurement data: Data can be saved, loaded, and deleted by operating the instrument.
- -1. Date and time
- -2. Resistance value, voltage value, and temperature
- -3. Comparator threshold value and judgment result
- Profile information: Profile information can be saved, loaded, and deleted using a supported application (GENNECT Cross or GENNECT One).
- -1. Profile numbers: 1 to 100 (Data (2), (3), and (4) below are saved for each profile number)
- -2. Location: User-defined comment such as location of UPS
- -3. Device information: User-defined comment such as UPS management number
- -4. Battery number: 1 to 500 (start number, end number)
- Measurement Navigator:
- Operation: Announces the next battery number to be measured via a screen display and audio guidance.
- Audio output is generated by a connected mobile device when using the Z3210 and a supported application (GENNECT Cross).
- Preparations: Profile information that's been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument.
- Communication interface: USB
- Bluetooth® wireless communications (when Z3210 installed)
- Other functions: Temperature measurement (-10.0 to 60.0 °C), Zero-adjustment, Hold, Auto-hold, Auto-memory, Auto-power-save, Clock
- Power supply:
- LR6 (AA) Alkaline dry battery ×8
- Continuous operating time: About 8.3 hr. (without Z3210 installed), About 8.2 hr. (with Z3210 installed and wireless communications active)
- Dimensions and mass:
- 199 mm (7.83 in)W × 132 mm (5.20 in)H × 60.6 mm (2.39 in)D (with protector), 960 g (33.9 oz) (including batteries and protector)
- Accessories:
- Carrying Case C1014 ×1, Protector Z5041 ×1, Fuse Set Z5050 ×1, 0 Adj Board ×1, Neck strap ×1, USB cable ×1, Application software CD (GENNECT One) ×1, AA alkaline battery (LR6) ×8, User Manual ×1