Hioki-3174 AC AUTOMATIC INSULATION/WITHSTANDING HiTESTER
Ensure Insulation and Withstand Voltage with Contact Check
Key Features and Functions
- Continuous testing of insulation (500/1000 V) and withstand voltage (100 VA transformer capacity)
- Full remote operation when used in combination with the Safety Test Data Management Software 9267
- Save up to 8 test settings each for the withstanding and insulation testing modes
- Precise test voltage without power voltage dependency is generated using the PWM method
Documents and Software:
Availability:
Call or email for delivery time
The AC Automatic Insulation/Withstanding Tester 3174 is a low-cost solution featuring contact check functionality as well as a stabilized power supply to prevent the reduced test reliability that can result from these issues.
Key Specifications:
Withstanding test section:
- Testing voltage: 0.2 V AC to 5.00 kV AC
- Voltage setting: Digital setting, Setting resolution: 0.01 kV
- Waveform/Frequency: Sine wave (Distortion ratio 5 % or less at no load), 50/60 Hz selectable
- Current measurement: 0.01 mA to 20.0 mA, True RMS rectified (digital display)
- Measurement range: 10 mA (0.01 mA resolution), 20 mA (0.1 mA resolution)
- Voltage meter: Accuracy: ±1.5 % rdg. (1000 V or more), ±15 V (less than 1000 V), True RMS rectified
- Judgment function: Window comparator method (Digital setting)
Insulation test section:
- Testing voltage: 500 V DC, 1000 V DC
- Unloaded voltage: 1 to 1.2 times rated voltage
- Rated testing current: 1 to 1.2 mA, Shorted current: 4 to 5 mA (at 500 V), 2 to 3 mA (at 1000 V)
- Measurement range, Accuracy: 0.5 MΩ to 999 MΩ (at 500 V), and 1 MΩ to 999 MΩ (at 1000 V): ±4 % rdg.,
- 1000 MΩ to 2000 MΩ: ±8 % rdg.
- Judgment function: Window comparator method (Digital setting)
Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Description
Reviews
Query on the Item
The AC Automatic Insulation/Withstanding Tester 3174 is a low-cost solution featuring contact check functionality as well as a stabilized power supply to prevent the reduced test reliability that can result from these issues.
Key Specifications:
Withstanding test section:
- Testing voltage: 0.2 V AC to 5.00 kV AC
- Voltage setting: Digital setting, Setting resolution: 0.01 kV
- Waveform/Frequency: Sine wave (Distortion ratio 5 % or less at no load), 50/60 Hz selectable
- Current measurement: 0.01 mA to 20.0 mA, True RMS rectified (digital display)
- Measurement range: 10 mA (0.01 mA resolution), 20 mA (0.1 mA resolution)
- Voltage meter: Accuracy: ±1.5 % rdg. (1000 V or more), ±15 V (less than 1000 V), True RMS rectified
- Judgment function: Window comparator method (Digital setting)
Insulation test section:
- Testing voltage: 500 V DC, 1000 V DC
- Unloaded voltage: 1 to 1.2 times rated voltage
- Rated testing current: 1 to 1.2 mA, Shorted current: 4 to 5 mA (at 500 V), 2 to 3 mA (at 1000 V)
- Measurement range, Accuracy: 0.5 MΩ to 999 MΩ (at 500 V), and 1 MΩ to 999 MΩ (at 1000 V): ±4 % rdg.,
- 1000 MΩ to 2000 MΩ: ±8 % rdg.
- Judgment function: Window comparator method (Digital setting)
Do you have any questions on this item?