GW-INSTEK AEL-5012 AC/DC Electronic Load, 350 or 425 V, 112.5 A, 11250 W
Key Features and Functions
- Maximum Power: 11250 W
- Maximum Voltage: Choice of 350 and 425 Volt
- Maximum Current 112.5 A
- CC, Linear CC, CR, CV, CP and AC Rectifier Load Mode
- Frequency Range : DC, 40~440Hz
- Turbo Mode for 2 Times the Current and Power of Electronic Load within 1 Second
- Three Units Parallel up to 90kW and Three-phase ? or Y Load Connection Can be Synchronized Control by One Master Unit
- Loading and Unloading Angle Control; 0~359 Degree is Settable
- Positive Half-cycle or Negative Half-cycle Loading
- Supports SCR/TRIAC Current Phase Modulation Waveforms,90 Degree Trailing Edge and Leading Edge
- Optional Interface : GPIB?RS232?USB?LAN
Documents and Software Solutions:
GW Instek launches 20 models of the AEL-5000 series AC/DC electronic loads.
The power range of a single unit is from 1875W to 22500W, and up to 8 units can be connected in parallel. The maximum power of single-phase parallel connection can reach 180kW, and the total power of 3-phase can reach 540kW, which are suitable for UPS, Inverter/Breaker, AC Power Source, Battery, Fuse/Breaker, DC Power Source and other applications.
The AEL-5000 series has built-in precision measurement circuits such as 16-bit A/D and DSP to provide accurate measurement items, which include voltage root mean square value (Vrms), current root mean square value (Arms), and watt value (Watt), volt-ampere (VA), crest factor (CF), power factor (PF), total harmonic distortion (THD), voltage total harmonic distortion (VTHD), current total harmonic distortion (ITHD) , peak current (Ipeak), maximum current (Amax), minimum current (Amin), maximum voltage (Vmax), minimum voltage (Vmin), time measurement. In addition, built-in test modes include UPS Efficiency, PV Inverter Efficiency, UPS Back-up time, Battery Discharge time, UPS transfer time, Fuse/Breaker Trip/Non-Trip, short circuit simulation, OCP, OPP and other test modes.
The AEL-5000 series has the Turbo mode (ON or OFF can be selected) design, which can increase the current and power of the electronic load by 2 times in one second. For test applications that require transient high power and large current such as transient overload test of protective components or short circuit of Fuse/Breaker and AC power supply, OCP and OPP tests etc.. The Turbo mode provides the most economical solution.
See table below to select the product of choice.
Product | Power Ratings |
---|---|
AEL-5002-350-18.75 | 350V/18.75A/1875W |
AEL-5003-350-28 | 350V/28A/2800W |
AEL-5004-350-37.5 | 350V/37.5A/3750W |
AEL-5006-350-56 | 350V/56A/5600W |
AEL-5008-350-75 | 350V/75A/7500W |
AEL-5012-350-112.5 | 350V/112.5A/11250W |
AEL-5015-350-112.5 | 350V/112.5A/15000W |
AEL-5019-350-112.5 | 350V/112.5A/18750W |
AEL-5023-350-112.5 | 350V/112.5A/22500W |
AEL-5002-425-18.75 | 425V/18.75A/1875W |
AEL-5003-425-28 | 425V/28A/2800W |
AEL-5004-425-37.5 | 425V/37.5A/3750W |
AEL-5006-425-56 | 425V/56A/5600W |
AEL-5008-425-75 | 425V/75A/7500W |
AEL-5012-425-112.5 | 425V/112.5A/11250W |
AEL-5015-425-112.5 | 425V/112.5A/15000W |
AEL-5019-425-112.5 | 425V/112.5A/18750W |
AEL-5023-425-112.5 | 425V/112.5A/22500W |
AEL-5003-480-18.75 | 480V/18.75A/2800W |
AEL-5004-480-28 | 480V/28A/3750W |
GW Instek launches 20 models of the AEL-5000 series AC/DC electronic loads.
The power range of a single unit is from 1875W to 22500W, and up to 8 units can be connected in parallel. The maximum power of single-phase parallel connection can reach 180kW, and the total power of 3-phase can reach 540kW, which are suitable for UPS, Inverter/Breaker, AC Power Source, Battery, Fuse/Breaker, DC Power Source and other applications.
The AEL-5000 series has built-in precision measurement circuits such as 16-bit A/D and DSP to provide accurate measurement items, which include voltage root mean square value (Vrms), current root mean square value (Arms), and watt value (Watt), volt-ampere (VA), crest factor (CF), power factor (PF), total harmonic distortion (THD), voltage total harmonic distortion (VTHD), current total harmonic distortion (ITHD) , peak current (Ipeak), maximum current (Amax), minimum current (Amin), maximum voltage (Vmax), minimum voltage (Vmin), time measurement. In addition, built-in test modes include UPS Efficiency, PV Inverter Efficiency, UPS Back-up time, Battery Discharge time, UPS transfer time, Fuse/Breaker Trip/Non-Trip, short circuit simulation, OCP, OPP and other test modes.
The AEL-5000 series has the Turbo mode (ON or OFF can be selected) design, which can increase the current and power of the electronic load by 2 times in one second. For test applications that require transient high power and large current such as transient overload test of protective components or short circuit of Fuse/Breaker and AC power supply, OCP and OPP tests etc.. The Turbo mode provides the most economical solution.
See table below to select the product of choice.
Product | Power Ratings |
---|---|
AEL-5002-350-18.75 | 350V/18.75A/1875W |
AEL-5003-350-28 | 350V/28A/2800W |
AEL-5004-350-37.5 | 350V/37.5A/3750W |
AEL-5006-350-56 | 350V/56A/5600W |
AEL-5008-350-75 | 350V/75A/7500W |
AEL-5012-350-112.5 | 350V/112.5A/11250W |
AEL-5015-350-112.5 | 350V/112.5A/15000W |
AEL-5019-350-112.5 | 350V/112.5A/18750W |
AEL-5023-350-112.5 | 350V/112.5A/22500W |
AEL-5002-425-18.75 | 425V/18.75A/1875W |
AEL-5003-425-28 | 425V/28A/2800W |
AEL-5004-425-37.5 | 425V/37.5A/3750W |
AEL-5006-425-56 | 425V/56A/5600W |
AEL-5008-425-75 | 425V/75A/7500W |
AEL-5012-425-112.5 | 425V/112.5A/11250W |
AEL-5015-425-112.5 | 425V/112.5A/15000W |
AEL-5019-425-112.5 | 425V/112.5A/18750W |
AEL-5023-425-112.5 | 425V/112.5A/22500W |
AEL-5003-480-18.75 | 480V/18.75A/2800W |
AEL-5004-480-28 | 480V/28A/3750W |